1.
Respir Care ; 68(3): 384-391, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36750259

RESUMO

BACKGROUND: Mechanical ventilation of the neonate requires ventilators than can deliver precise and accurate tidal volume (VT) and PEEP to avoid lung injury. Due to small neonatal VT and the disproportionate effect of endotracheal tube leak in these patients, accomplishing precise and accurate VT delivery is difficult. Whereas neonatal ICU ventilators are validated in this population, thorough studies testing the performance of anesthesia ventilators in delivering small VT in neonates are lacking. METHODS: Three anesthesia ventilators, Dräger Apollo, GE Avance, and Getinge Flow-i; and 2 ICU ventilators, Medtronic PB980 and Nihon Kohden NKV-550, were tested under volume control mode at VT of 5, 20, 40, and 60 mL. Three combinations of lung compliance and airway resistance were tested using a Servo ASL 5000 lung simulator. RESULTS: In a scenario without leak, the measured VT was greater than the set VT by > 10% in the Apollo (21.0% [18.8-26.0]); measured VT was less than the set VT by > 10% in the Flow-i (-19% [-20.8 to -18.7]). The Avance, PB980, and NKV-550 presented a volume error < 10% (-9.50% [-10.8 to -4.4], -5.8% [-11.8 to -3.5], and 5.4% [-4.5 to 18.9], respectively). Considering all combinations of set VT, leaks, and respiratory mechanics, none of the anesthesia ventilators were able to deliver a median measured VT within a 10% error. The bias between measured VT and set VT varied widely among ventilators (from 4.27 mL to -10.59 mL). Additionally, in the Apollo ventilator, PEEP was underdelivered with the largest leak value. CONCLUSIONS: Our results suggest that in comparison with the 2 neonatal ICU ventilators tested, the anesthesia ventilators did not greatly differ in terms of VT delivery in the presence of a gas leak.


Assuntos
Anestesia , Ventiladores Mecânicos , Recém-Nascido , Humanos , Volume de Ventilação Pulmonar , Pulmão , Unidades de Terapia Intensiva Neonatal
2.
J Clin Med Res ; 12(12): 787-793, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33447312

RESUMO

BACKGROUND: Improvement in short-term outcomes after kidney transplant has been achieved by using different induction and maintenance therapeutic approaches. Long-term outcomes have not matched the expectations of the transplant stakeholders. Our study aimed to address the early impact of induction agents on long-term outcome of kidney transplant when measured by iothalamate clearance. METHODS: All adult kidney transplant recipients between January of 2012 and December of 2016 were reviewed. Six hundred forty-nine patients were divided into three groups based on the induction agent (basiliximab, alemtuzumab, and thymoglobulin). Protocoled 4 months and 48 months kidney allograft function evaluations with iothalamate clearance test were compared among the three groups. RESULTS: Patients who received basiliximab were significantly older with no difference among African American and Caucasians. The 48 months assessment showed significant decline in median iothalamate clearance in basiliximab group at 49 mL/min vs. alemtuzumab group 64.8 mL/min and thymoglobulin 60 mL/min with P = 0.007. The basiliximab group developed a significant higher proteinuria measured by spot urine to creatinine ratio at 48 months. CONCLUSIONS: The use of basiliximab as an induction agent for kidney transplant is associated with significant decline in kidney function 4 years post transplantation when measured by iothalamate clearance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...